Kingspan Therma TT47 is a tapered high performance, fibre-free rigid thermoset insulation, faced on both sides with a coated glass tissue autohesively bonded to the insulation core during manufacture.
Product Dimensions | 1200 mm x 1200 mm (1.44 m²) |
Product thickness | Systems with a 1:30 & 1:40 fall: 60 mm minimum Systems with a 1:60 & 1:80 fall: 30 mm minimum All systems: Unlimited maximum* |
Taper Gradients | Falls of 1:30, 1:40, 1:60 and 1:80** |
Assumption and Key
The roof insulation shall be Kingspan Therma TT47____ mm thick, comprising a CFC/HCFC-free and zero Ozone Depletion Potential (ODP) rigid thermoset insulation core with coated glass tissue facings on both sides, manufactured under a management system certified to ISO 9001:2015, BS / ISO 14001:2015 and OHSAS 18001:2007 by Kingspan Insulation Limited and shall be installed in accordance with the instructions issued by them.
A Project Specific Warranty provided by Kingspan Insulation must be submitted.
Specify with:
Management Standards
Standard | Management System |
ISO 9001:2008 | Quality Management |
ISO 14001:2004 | Environmental Management |
OHSAS 18001:2007 | Health and Safety Management |
Requirement | Rigid polyisocyanurate (PIR) and polyurethane (PUR) products for building end–use applications |
BS 4841-3 | Specification for laminated boards (roofboards) with auto–adhesively or separately bonded facings for use as roof board thermal insulation under built–up bituminous roofing membranes |
BS 4841-4 | Specification for laminated boards (roofboards) with auto–adhesively or separately bonded facings for use as roofboard thermal insulation under single−ply roofing membranes |
Spanning On Metal Decks
Trough Opening (mm) | Minimum Insulant Thickness (mm) |
≤75 | 25 |
76 - 100 | 30 |
101 - 125 | 35 |
126 - 150 | 40 |
151 - 175 | 45 |
176 - 200 | 50 |
201 - 225 | 55 |
226 - 250 | 60 |
Product Testing
Characteristic | Standard | Result |
Compressive Strength | AS 2498.3 | Typically exceeds 150 kPa at 10% compression |
Water Vapour Resistance | AS 2498.5 | > 7 MN·s/g |
Fire Performance
Kingspan Therma TT47, when subjected to the British and Australian Standard fire tests specified in the table below, will achieve the result shown, when waterproofed with a single–ply waterproofing membrane.Test | Result |
BS 476-3: 2004 (External fire exposure roof test) |
Dependent on single-ply membrane adopted |
AS 1530.3 (Ignitability, Flame Spread, Heat Release, Smoke Release) |
Spread of Flame Index: 0 Smoke Development Index: 5 |
AS 2122.1 (Flame Propagation AS 1366_ |
Complies |
Test | Result |
BS 476-3: 2004 | FAA Rating |
FM Certification
Kingspan Therma TT47 are certified as achieving Class 1 Insulated Steel Deck Pass to Factory Mutual Research Standards 4450 (Approval Standard for Class 1 Insulated Steel Deck Pass) and 4470 (Approval Standard for Single–Ply, Polymer–Modified Bitumen Sheet, Built–Up Roof (BUR) and Liquid Applied Roof Assemblies for use in Class 1 Non-combustible Roof Deck Construction), subject to the conditions of approval as a roof insulation product for use in Class 1 roof constructions as described in the current edition of the Factory Mutual Research Approval Guide.