 Kingspan Therma TT47

 

Kingspan Therma TT47 is a tapered high performance, fibre-free rigid thermoset insulation, faced on both sides with a coated glass tissue autohesively bonded to the insulation core during manufacture.

  • FM approved for Class 1 steel deck roof assemblies
  • Insulation and drainage in one
  • Easy to handle and install
      DOWNLOAD BROCHURE

       Back to Kingspan Insulation

      Blue Line

       

      Product Data Table

      Product Dimensions 1200 mm x 1200 mm (1.44 m²)
      Product thickness Systems with a 1:30 & 1:40 fall: 60 mm minimum
      Systems with a 1:60 & 1:80 fall: 30 mm minimum
      All systems: Unlimited maximum*
      Taper Gradients Falls of 1:30, 1:40, 1:60 and 1:80**

      *Packer boards will be required above a specific thickness.
      **For information regarding tapered roof designs incorporating Kingspan Therma TT47 in a wider range of falls please contact the Waterproofing Direct Technical Service team at admin@waterproofingdirect.com.au.

       

      Blue Line

      R-values

      Assumption and Key

      The effective thermal conductivity and thermal resistance of the insulation in a tapered roofing system is specific to the individual roof design. The Kingspan Insulation Tapered Roofing Department performs calculations to determine these values in accordance with Annex C of BS EN ISO 6946: 2007 (Building components and Building elements – Thermal resistance and thermal transmittance – Calculation method) as part of the scheme design process.

       

      Blue Line

      Specification Guide

      The roof insulation shall be Kingspan Therma TT47____ mm thick, comprising a CFC/HCFC-free and zero Ozone Depletion Potential (ODP) rigid thermoset insulation core with coated glass tissue facings on both sides, manufactured under a management system certified to ISO 9001:2015, BS / ISO 14001:2015 and OHSAS 18001:2007 by Kingspan Insulation Limited and shall be installed in accordance with the instructions issued by them.

      A Project Specific Warranty provided by Kingspan Insulation must be submitted.

      Specify with:NatSpec logo

      Blue Line

       

      Testing and Data Table

      Management Standards

      Standard Management System
      ISO 9001:2008 Quality Management
      ISO 14001:2004 Environmental Management
      OHSAS 18001:2007 Health and Safety Management

      Kingspan Therma TT47 are also manufactured to the highest standards in accordance with the requirements of:

      Requirement Rigid polyisocyanurate (PIR) and polyurethane (PUR) products for building end–use applications
      BS 4841-3 Specification for laminated boards (roofboards) with auto–adhesively or separately bonded facings for use as roof board thermal insulation under built–up bituminous roofing membranes
      BS 4841-4 Specification for laminated boards (roofboards) with auto–adhesively or separately bonded facings for use as roofboard thermal insulation under single−ply roofing membranes

       

      Spanning On Metal Decks

      Trough Opening (mm) Minimum Insulant Thickness (mm)
      ≤75 25
      76 - 100 30
      101 - 125 35
      126 - 150 40
      151 - 175 45
      176 - 200 50
      201 - 225 55
      226 - 250 60

      Product Testing

      Characteristic Standard Result
      Compressive Strength  AS 2498.3 Typically exceeds 150 kPa at 10% compression
      Water Vapour Resistance AS 2498.5 > 7 MN·s/g

      Fire Performance

      Kingspan Therma TT47, when subjected to the British and Australian Standard fire tests specified in the table below, will achieve the result shown, when waterproofed with a single–ply waterproofing membrane.

      Test Result
      BS 476-3: 2004
      (External fire exposure roof test)
      Dependent on single-ply membrane adopted
      AS 1530.3
      (Ignitability, Flame Spread, Heat Release, Smoke Release)
      Spread of Flame Index: 0
      Smoke Development Index: 5
      AS 2122.1
      (Flame Propagation AS 1366_
      Complies 
      Kingspan Therma TT47, when subjected to the British Standard fire test, specified in the table below, will achieve the result shown when waterproofed with 3 layer built–up felt and a loading coat of 10 mm chippings. For specifications without the chippings please consult the manufacturer of the mineral surfaced cap sheet for their fire classification details.
       
      Test Result
      BS 476-3: 2004 FAA Rating

      Further details on the fire performance of Kingspan Insulation products may be obtained from the WPD Group Technical Team.

      FM Certification

      Kingspan Therma TT47 are certified as achieving Class 1 Insulated Steel Deck Pass to Factory Mutual Research Standards 4450 (Approval Standard for Class 1 Insulated Steel Deck Pass) and 4470 (Approval Standard for Single–Ply, Polymer–Modified Bitumen Sheet, Built–Up Roof (BUR) and Liquid Applied Roof Assemblies for use in Class 1 Non-combustible Roof Deck Construction), subject to the conditions of approval as a roof insulation product for use in Class 1 roof constructions as described in the current edition of the Factory Mutual Research Approval Guide.

       

      Blue Line

       